Class EmptyAnimation
- All Implemented Interfaces:
ControlRequest, Cloneable
-
Field Summary
FieldsModifier and TypeFieldDescriptionintThe slot of this animation, within [0, 7].doubleThe frequency at which this control will update. -
Constructor Summary
ConstructorsConstructorDescriptionEmptyAnimation(int Slot) An empty animation, clearing any animation in the specified slot. -
Method Summary
Modifier and TypeMethodDescriptionclone()Gets information about this control request.getName()Gets the name of this control request.sendRequest(CANBus network, int deviceHash) Sends the control request to the device.toString()withSlot(int newSlot) Modifies this Control Request's Slot parameter and returns itself for method-chaining and easier to use request API.withUpdateFreqHz(double newUpdateFreqHz) Sets the frequency at which this control will update.withUpdateFreqHz(Frequency newUpdateFreqHz) Sets the frequency at which this control will update.
-
Field Details
-
Slot
public int SlotThe slot of this animation, within [0, 7]. Each slot on the CANdle can store and run one animation. -
UpdateFreqHz
public double UpdateFreqHzThe frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.
-
-
Constructor Details
-
EmptyAnimation
public EmptyAnimation(int Slot) An empty animation, clearing any animation in the specified slot.- Parameters:
Slot- The slot of this animation, within [0, 7]. Each slot on the CANdle can store and run one animation.
-
-
Method Details
-
getName
Description copied from interface:ControlRequestGets the name of this control request.- Specified by:
getNamein interfaceControlRequest- Returns:
- Name of the control request
-
toString
-
sendRequest
Description copied from interface:ControlRequestSends the control request to the device. Users should callsetControl()on the device instead.- Specified by:
sendRequestin interfaceControlRequest- Parameters:
network- Device networkdeviceHash- Device hash- Returns:
- Status code of sending the request
-
getControlInfo
Gets information about this control request.- Specified by:
getControlInfoin interfaceControlRequest- Returns:
- Map of control parameter names and corresponding applied values
-
withSlot
Modifies this Control Request's Slot parameter and returns itself for method-chaining and easier to use request API.The slot of this animation, within [0, 7]. Each slot on the CANdle can store and run one animation.
- Parameters:
newSlot- Parameter to modify- Returns:
- Itself
-
withUpdateFreqHz
Sets the frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.
- Specified by:
withUpdateFreqHzin interfaceControlRequest- Parameters:
newUpdateFreqHz- Parameter to modify- Returns:
- Itself
-
withUpdateFreqHz
Sets the frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.
- Specified by:
withUpdateFreqHzin interfaceControlRequest- Parameters:
newUpdateFreqHz- Parameter to modify- Returns:
- Itself
-
clone
-